Commercial Fire Doors
Reliable fire protection for entry, industrial, security and healthcare applications
Our commercial fire doors are manufactured and tested with Australian conditions in mind, and can be configured to suit offices, entry points, industrial facilities, security-sensitive areas and healthcare environments.

Our fire doors are manufactured and rigorously tested to meet the Australian standard.

Our range of fire-rated doors are available in custom and standard sizes.

Our fire-rated doors can be customised to seamlessly fit the design of your building.

We offer timber and steel fire-doors for commercial applications.
*Larnec does not provide site measures or installations, however we can still help you with a solution. If you or your builder have the necessary measurements, simply send them through and we’ll arrange a quote based on the information provided.
Quick Answer
Commercial fire doors are certified door systems designed to help contain fire and smoke for a defined period, supporting safe evacuation and helping buildings work towards compliance with the National Construction Code (NCC) and AS 1905.1. Larnec’s range includes configurations for general commercial use, entry points, industrial environments, security applications, healthcare facilities, and a range of other building types, in timber plywood and steel-clad options.
What is a Commercial Fire Door?
A commercial fire door is a complete system — door leaf, frame, seals and hardware — tested to resist the passage of fire and smoke, helping contain fire and protect escape routes.
Larnec commercial fire doors can be configured to suit a wide range of commercial projects and are commonly specified for applications such as:
- Standard commercial — offices, retail and public buildings
- Entry — key access points combining fire protection with everyday usability
- Industrial — factories, warehouses and processing facilities
- Security — fire-rated construction with hardware aimed at improving forced-entry resistance
- Healthcare — hospitals and clinics, balancing fire protection with hygiene and accessibility
Every commercial fire door is supplied as a tested door system. Depending on the application, the approved fire-rated hardware, finish and installation method may vary to suit the project requirements and wall type.
Where Are They Used?
- Warehouses and Factories
- Commercial Offices and Retail
- Hospitals and Aged Care
- Schools
- Main Building Entries
- Storage and Asset-Protection Areas
- Modular Buildings
- The list goes on due to the versatility of the door system.
Compliance in Australia
Commercial fire doors are generally expected to align with the NCC, AS 1905.1 (fire-resistant doorsets) and AS 1530.4 (fire resistance testing). Doors are assigned a Fire Resistance Level (FRL) as part of certification. Because FRL requirements, clearances and inspection intervals vary by building class and application, confirm the specifics for your project with your certifier and the current NCC
Timber Plywood vs Steel Fire Doors — Which Is Right for Your Project?
| Feature | Timber Plywood Fire Doors | Steel-Clad Fire Doors |
|---|---|---|
| Appearance | Traditional, warm aesthetic — suits commercial offices, schools, hotels and healthcare interiors | Industrial, robust finish — suits warehouses, manufacturing, and high-traffic environments |
| Fire Rating | Available in 60 and 120-minute FRL ratings | Available in 60 and 120-minute FRL ratings |
| Durability | Suited to low-to-medium impact environments | Higher impact resistance — better for industrial and heavy-use applications |
| Customisation | Can be painted, stained, or veneered to match interior design | Can be supplied in a range of Colorbond colours |
| Best For | Offices, schools, hospitals, aged care, retail, apartments and hotels | Warehouses, factories, modular buildings, external openings |
| Australian Standard | AS 1905.1 compliant | AS 1905.1 compliant |
| Supplied By Larnec | ✓ Yes | ✓ Yes |
Compliance Checklist
- Fire-rated door leaf and frame supplied as a tested system
- Certification documentation for the FRL
- Intumescent seals and a self-closing mechanism (where required)
- Hardware designed for fire-rated applications
- Installation completed within specified clearances
- A certification tag or label on the door
Common Mistakes to Avoid
- Installation gaps that fall outside specified tolerances
- Hardware that hasn’t been assessed as part of the certified system
- Missing, damaged or removed certification labels
- Unreviewed modifications made after installation, such as added locks
- Irregular maintenance of hinges, closers and seals
- Overlooking hygiene requirements in healthcare and clinical settings
Our Range Of
Commercial Fire Doors
*All doors are manufactured and rigorously tested to meet Australian standards.
Custom Solutions
Fire doors can be configured to suit architectural requirements, specific opening sizes, and combined features across applications — for example, an entry door with added fire-rated security hardware.

Important Information Before Ordering
Larnec doesn’t provide site measurements or installation services. Share your opening sizes, required application, wall type and installation method, and project specifications, and we’ll put together a tailored quote.
Industries We Support
Commercial fire doors can be supplied for projects across virtually any industry. Common applications include commercial offices, education, healthcare, industrial facilities, manufacturing, warehousing, retail, government buildings and modular construction, with configurations tailored to suit each project’s requirements.
Trusted Solutions. Proven Process.
01
Consultation
Our team works with you to understand your requirements and identify the right solution.
02
Specification & Ordering
We confirm product specifications, documentation, and lead times before production begins.
03
Manufacturing
Products are manufactured in Australia using efficient production processes and rigorous quality standards.
04
Delivery
We deliver Australia-wide to project sites, businesses, warehouses, and consolidation centres.
Frequently asked questions
Larnec commercial fire doors are available with Fire Resistance Levels (FRLs) of up to 120 minutes (2 hours), depending on the tested door system and configuration.
Yes — Larnec’s custom fire doors are designed to be configured to suit a range of architectural styles, engineered and manufactured with a focus on functionality, durability and aesthetic appeal.
Generally the NCC, AS 1905.1 and AS 1530.4, plus certification labelling from a registered testing authority. Confirm the project-specific detail that applies to your building with your certifier.
Regularly clean the door and frame, keep the sill area free of debris, and check hinges, closers, locks and seals so the door continues to open, close, latch and seal as intended. In healthcare settings this should form part of routine cleaning protocols. Your certifier can confirm a suitable inspection schedule, and Larnec can arrange fire door inspections on request.
Yes. Fire-rated security hardware can be incorporated into a certified fire door system where required. Adding non-assessed hardware after installation may affect certification, so any security upgrades should be specified as part of the original tested door system.
Contact our team with your specifications, required application and details about your building, and we’ll help match you with a suitable option from our range.
Start Your Project
Get a free expert consultation today
Get everything you need to specify Larnec in your next project.
Speak to our team
Trusted by Leading Brands Across Australia